Managing Pressure with Airtac 4V210-08: Safety & Tips

Managing Pressure with Airtac 4V210-08

The Airtac 4V210-08 operates within a specific pressure window to ensure the internal pilot functions correctly.

Technical Pressure Specifications

  • Operating Pressure: 0.15MPa to 0.8MPa (21 - 114 PSI).
  • Proof Pressure: 1.2MPa (174 PSI).

Why the Minimum Matters

Because it is an Internal Pilot valve, it uses the inlet air pressure to push the spool. If your system pressure drops below 0.15MPa, the valve may fail to shift completely, leading to constant air leakage through the exhaust ports.

Back to blog